Water and beverages · WB-08 · Energy in bottle production
The tariff has gone up. Where the energy goes is not visible.
From 1 June 2026, the electricity tariff for legal entities increased. In PET bottle production, a large share of energy goes to blow moulding and compressed air, but it is usually visible only on a single plant-wide meter.
Platform: Plant Pulse
Electricity tariff for legal entities, UZS/kWh, from 01.06.2026. Previously 1,000 UZS.1
Natural gas price, UZS/m³, from 01.06.2026.1
According to an industry publication, on some lines the blow moulding machine can account for this share of total energy consumption.2
To reduce energy use, you first need to know how much goes into each bottle.
Who it is for
- Chief Power Engineer
- Consumption by consumer.
- Production Director
- Energy by line.
- Finance Director
- Tariff and share in production cost.
- Plant Owner
- Payback of energy-saving projects.
Where the problem lies
Single meter
Total plant consumption is known, but blow moulding, compressor and chiller consumption are not visible separately.
Compressed air
If pressure is higher than required or air leaks, the compressor runs more than necessary.
Idle running
When the line stops, blow moulding and chilling equipment may keep running.
Not calculated per unit of output
If consumption per 1,000 bottles is unknown, savings cannot be proven.
How the loss is calculated
| Energy cost | kWh per 1,000 bottles × tariff (UZS/kWh) × annual output (thousands of bottles) |
|---|---|
| Idle running | stoppage hours (h/year) × equipment power (kW) × tariff (UZS/kWh) |
| Compressed air | compressor consumption (kWh/year) × share due to excess pressure × tariff (UZS/kWh) |
| Tariff change | annual consumption (kWh/year) × (new − old tariff, UZS/kWh) |
Calculate with your data
Bottle Production Energy: Specific Consumption per 1,000 Bottles and Annual Cost
This calculator estimates electricity cost for a single line.
Use spaces for thousands and a dot or comma for decimals. Use the same currency throughout.
Values stay in this page and are not sent to the server.
Scenario estimate
0 / 4 values entered
Enter your operating figures to see the estimate.
Calculate the current specific consumption from meter data over a representative period. It should already include consumption during idling and stoppages. For this reason, do not add idling or compressed-air losses separately, as that would double count them. The target consumption is only a scenario you enter, and it is not presented as attainable; verify it with an energy audit or measurements. Enter the current tariff you actually pay. The calculator does not forecast tariff changes. The following are excluded: investment and installation, maintenance, demand charges, reactive energy, taxes, and effects on quality or output. Changes to line programming should only be made with the equipment supplier's approval.
Formulas and assumptions
This calculator estimates electricity cost for a single line. Its scope covers the blow moulder, compressor and chiller. You enter the current specific consumption measured from meters (kWh per 1,000 bottles) and a target consumption that you define yourself. The results are shown in UZS per year: current cost, scenario cost and the difference between them. The difference is the effect within your scenario, not an achieved result. All figures are estimates, not guaranteed savings.
- Current energy cost per 1,000 bottles
- Current specific consumption (kWh per 1,000 bottles) is multiplied by the tariff (UZS per kWh).
- Current annual energy cost
- Current specific consumption (kWh per 1,000 bottles) × annual bottles ÷ 1,000 gives annual kWh. This is then multiplied by the tariff (UZS per kWh).
- Annual energy cost in target scenario
- Target specific consumption (kWh per 1,000 bottles) × annual bottles ÷ 1,000 × tariff (UZS per kWh). Output and tariff are assumed unchanged.
- Annual difference in scenario (not guaranteed)
- (Current − target consumption, kWh per 1,000 bottles) × annual bottles ÷ 1,000 × tariff (UZS per kWh). If the target exceeds current consumption, the result is set to 0.
Facts and global practice
Cabinet of Ministers Resolution No. 243 of 15.05.2026, effective 01.06.2026
Electricity tariff for Group I, II and IV consumers is 1,100 UZS/kWh; for Groups II and IV it was previously 1,000 UZS.1
Same resolution
Natural gas for all consumers (with certain category exceptions) is 2,000 UZS/m³.1
Industry publication, beverage bottling plant example
The blow moulding machine can account for up to 70% of total energy consumption; most of this is attributable to compressed air.2
UzBev association, no figures given
Energy and packaging prices have increased.3
Energy consumption depends on the line, bottle size and equipment age. For comparison, consumption should be calculated per 1,000 bottles or per litre.
Energy accounting by consumer
Meters are installed on the main consumers, and consumption is displayed alongside line output.
- 01Meters
- Blow moulding
- Compressor
- Chiller
- 02Production
- Line status
- Unit counter
- Format
- 03Calculation
- kWh / 1,000 units
- Idle running
- UZS at tariff
- 04Analysis
- Shift and format
- Trend
- Saving measures
Modules
The current maturity level is shown next to each module.
| Energy monitoring | Meters and accounting by consumer | In development |
|---|---|---|
| Line signal collection | Operating status and unit counters | Engineering capability |
How we start
- 01
Energy audit
Temporary measurement on the main consumers.
Outcome: consumption breakdown.
- 02
Meters
Permanent meters and connection.
Outcome: daily data.
- 03
Measures
Measures on idle running, pressure and leaks.
Outcome: consumption is re-measured.
- 04
Control
Monthly report.
Outcome: Consumption trend per 1,000 bottles.
What is measured
| Specific consumption | kWh / 1,000 bottles, by line | Meters, line |
|---|---|---|
| Blow moulding share | Blow moulding / total consumption | Meters |
| Idle running | Consumption while the line is stopped | Meters, line |
| Energy cost | UZS / 1,000 bottles | Calculation |
What is needed to start
- Chief Power Engineer
- Electrical diagram and list of meters
- Line operating schedule
- Time window for meter installation
What we do not promise
- Fixed timeline and price without an audit
- Government resolutions and their deadlines
- Changes to line software without the equipment supplier's approval
- Unmeasured results or savings
- Tariff changes
- Savings of a specific percentage
Self-check
- Is blow moulding machine consumption measured separately?
- Is compressor consumption measured separately?
- Is chiller consumption measured separately?
- Is kWh per 1,000 bottles known?
- Is equipment switched off when the line stops?
- Is compressed air pressure set to actual demand?
- Are air leaks checked regularly?
- Has the new tariff been included in production cost?
- Is energy consumption compared across shifts?
- Is there a person responsible for energy?
Energy audit
We measure blow moulding, compressor and chiller consumption and calculate the energy cost per 1,000 bottles.
- Consumption breakdown
- Idle running and losses
- Plan of measures and meters
Other solutions in this industry
- WB-02Line speed after marking
- WB-03Code errors in distribution
- WB-04Code and stock reconciliation
- WB-05Total cost of ownership of a marking system
- WB-06Production lines during internet and power outages
- WB-07Filling Line Efficiency (OEE)
- WB-09Sugar: quota, excise and labelling
- WB-10Export batches and codes
Sources
- Cabinet of Ministers Resolution No. 243 of 15.05.2026. buxgalter.uz; gov.uz/ru/minenergy, 15.05.2026.
- Coca-Cola bottler reduces blowing pressure. foodprocessing.com.au.
- UzBev association statement. gazeta.uz, 30.03.2026.